Overview

This unit aims to provide the concepts and principles of electrical protection techniques in today's power systems. The unit also covers different types of protection systems, application of protection to generators, motors, transformers, and electrical system communications for protection application in of modern electrical energy system. Students will learn to analyse and detect different types of faults in power systems.

Requisites

Teaching Periods
Location
Start and end dates
Last self-enrolment date
Census date
Last withdraw without fail date
Results released date
Semester 1
Location
Hawthorn
Start and end dates
26-February-2024
26-May-2024
Last self-enrolment date
10-March-2024
Census date
31-March-2024
Last withdraw without fail date
12-April-2024
Results released date
02-July-2024
Semester 1
Location
Hawthorn
Start and end dates
26-February-2024
26-May-2024
Last self-enrolment date
10-March-2024
Census date
31-March-2024
Last withdraw without fail date
12-April-2024
Results released date
02-July-2024

Learning outcomes

Students who successfully complete this unit will be able to:

  • Describe the concept and principles of electrical protection systems (K2,K3,S1,S2)
  • Appraise and apply calculation methods for magnitude and angle of voltage and current for the digital relaying (K2,K3,S1,S2)
  • Calculate symmetrical/un-symmetrical fault currents, and analyse different fault detection techniques (K2,K3,S1,S2)
  • Design and coordination of overcurrent / directional overcurrent protection (K2,K3,S1,S2,S3)
  • Design of differential and distance protection systems (K2,K3,S1,S2,S3)

Teaching methods

Hawthorn

Type Hours per week Number of weeks Total (number of hours)
Face to Face Contact (Phasing out)
Lecture
2.00 12 weeks 24
Face to Face Contact (Phasing out)
Laboratory
2.00 12 weeks 24
Face to Face Contact (Phasing out)
Tutorial
1.00 12 weeks 12
Unspecified Learning Activities (Phasing out)
Independent Learning
7.50 12 weeks 90
TOTAL150

Assessment

Type Task Weighting ULO's
Applied ProjectIndividual/Group 35 - 65% 1,2,3,4,5 
AssessmentIndividual/Group 25 - 35% 2,4 
Test 1Individual 5 - 15% 1,2 
Test 2Individual 5 - 15% 2,3 

Hurdle

As the minimum requirements of assessment to pass a unit and meet all ULOs to a minimum standard, an undergraduate student must have achieved:

(i) an aggregate mark of 50% or more, and(ii) at least 40% in the Applied Project.Students who do not successfully achieve hurdle requirement (ii) will receive a maximum of 45% as the total mark for the unit.

Content

  • Basics and principles of power system protection
  • Understand and coprehend power system faults
  • Fault detection and analysis
  • Operating principles of Relays
  • Introducing different types of Circuit breakers and Current/Voltage transformers
  • Overcurrent and Directional overcurrent protection principles and coordinations
  • Distance and Differential protections
  • Microgrid and Renewable energy system rotection 